Bredent attachment, vks-oc-rs f 2.2 mm for 3i, Steri-Oss, hex-lock and Replace

for resilient and rigid females

dia 6 mm, distance height 2 mm Implant Analogue 4 mm dia
vks-oc-rs f 2.2. mm
Abutment
f 4 mm, distance height
2 mm
46000042
vks-oc-rs f 2.2. mm
Abutment
f 5 mm, distance height
2 mm
46000052
vks-oc-rs f 2.2. mm
Abutment
f 6 mm, distance height
2 mm
46000062
vks-oc-rs f 2.2. mm
Implant Analogue
f 4 mm46000004
dia 4 mm, distance height 4 mm
vks-oc-rs f 2.2. mm
Abutment
f 4 mm, distance height
4 mm
46000044
vks-oc-rs f 2.2. mm
Abutment
f 5 mm, distance height
4 mm
46000054
vks-oc-rs f 2.2. mm
Abutment
f 6 mm, distance height
4 mm
46000064
vks-oc-rs f 2.2. mm
Implant Analogue
f 5 mm46000005
4 mm, distance height 6 mm 5 mm, distance height 6 mm 6 mm, distance height 6 mm Implant Analogue 6 mm dia
vks-oc-rs f 2.2. mm
Abutment
f 4 mm, distance height
6 mm
46000046
vks-oc-rs f 2.2. mm
Abutment
f 5 mm, distance height
6 mm
46000056
vks-oc-rs f 2.2. mm
Abutment
f 6 mm, distance height
6 mm
46000066
vks-oc-rs f 2.2. mm
Implant Analogue
f 6 mm46000006
Screwdriver is, elbow Screwdriver is, manual, short angle measuring device axle abutment
Screwdriver is

elbow, 1 piece

46000010

Screwdriver is

manual, short, 1 piece

46000011

Angle measuring device

1 piece

46000100

vks-oc-rs f 2.2. mm
Axle Abutment,
2 pieces46000102 

Bredent Vario Snap vks-oc-rs

slide 2 slide 3 slide 4
After successful osseointegration of the implant, the mucous membrane is opened and the suitable vks-oc abutment is screwed in. The torque must be limited to 30 Ncm by using a vks-oc screwdriver. Abutments in the distance heights of 2, 4  and 6 mm are available. Distance sleeves are not required. The stud abutments can also be used as gingiva former. Prior to taking the impression, place the transfer matrixes onto the stud abutments. The transfer matrices are now in the total impression. Retention grooves ensure the firm position of the transfer matrices in the impression material. Prior to the fabrication of the model, laboratory implants are inserted into the transfer matrices. This way precise transfer of the position of the implants is guaranteed.
slide 6
The model precisely shows the position of the implants. Normally the implants have not been inserted in an entirely parallel position to each other so that divergence or convergences between several stud abutments result. The vks-oc system accepts maximum deviations of 15° to the planned angle of insertion. To determine from the vertical axle, axle abutments are placed onto the abutment analogue. A special angle measuring device represents the range of tolerance of the vks-oc system. In this example the deviation of the implants lies within the range of tolerance. Resilient Resilient Rigidvks-oc Abutments can be supplied with rigid or resilient matrixes.
matrixes can be integrated into a chrome cobalt framework or an acrylic denture.